Water Treatment System

MG Machine’s piston fillers are able to fill thick sauces, honey, and cosmetics with accuracy. Our tomato sauce filling machine & honey filling machine realize filling clean and accurately. Solutions for the daily chemical product filling machine customizable.

Smart Water Treatment for Your Source

The one-size-fits-all approach doesn ’t work in industrial water treatment. Contaminants in your raw water — whether from a well, municipal tap, or surface source — pose unique risks to your production quality, equipment life, and operating costs.

We design precision water treatment systems beginning with a clear diagnosis: your comprehensive water analysis report. Using this information, we tailor every stage of your treatment—pre-treatment through final disinfection—to provide you with water that reliably meets your precise product and process specifications.

Our technology delivers outstanding efficiency, reliability and affordability for a variety of markets, including the beverage and food processing, pharmaceutical and electronic industries.

Why Water Analysis Really Matters

Before designing any system, we require a detailed water quality analysis. This scientific report is the foundation, determining the necessary treatment processes to combat specific contaminants and protect your investment.

The Consequences of Inadequate Treatment vs. Our Customized Solution:

Water Quality IssueRisk if UntreatedOur Corresponding Tailored Treatment Method
High TurbidityClogs filters & membranes; increases downtime & maintenance.Strengthened multimedia filtration with optimized media layers; optional coagulant dosing.
High TDS (Salts)Poor product water purity; unsuitable for high-grade applications.Multi-stage Reverse Osmosis (RO); addition of Electrodeionization (EDI) for ultra-pure water.
High HardnessCauses severe scaling in boilers, RO membranes, and pipes, reducing efficiency.Automatic water softener (ion exchanger) or precision antiscalant dosing system.
High Residual ChlorineOxidizes and damages thin-film composite RO membranes irreversibly.Activated carbon filtration (99%+ removal) or sodium metabisulfite dosing.
High Iron & ManganeseStains products, fouls membranes, promotes bacterial growth.Specialized oxidation & manganese sand filtration or greensand filters.
High Organic Matter (COD)Leads to biofouling of RO systems, degrading performance.Enhanced activated carbon or Ultrafiltration (UF) as a pre-treatment barrier.
High Bacterial CountHygiene and product safety risk; potential for recalls.Integrated UV Sterilizer + Ozone dual-barrier disinfection system.

Core Products: Our Modular Treatment Units

Intelligent Pre-Treatment & Filtration Suite

Remove Suspended Solids, Organics and Hardness of Water Raw Water Buffer System: Food grade SUS304 storage tank with level control for consistent supply.

Quartz Sand Multi-Media Filter: It removes particles greater than 20 microns. Recommendation: Efficacy: Effluent turbidity <0.5 NTU, SDI ≤5.

Activated Carbon Filter: Adsorbs chlorine, odor and organics. Efficacy: Residual chlorine ≤0.1 mg/L, protecting the downstream RO.

Automatic Water Softener: Removes the ions that cause scaling (Ca²⁺, Mg²⁺). Efficacy: Output hardness <1.5 mg/L.Precision Cartridge Filter (5/1 micron) Final particulate guard. Efficacy: So that water entering the RO system is free from particles.

The Heart of Purification: Reverse Osmosis (RO) Systems

High-Efficiency Desalination and Purification Our RO systems are at the heart of desalination, providing: Professional Configuration: Adopt high quality membrane elements (DOW/Hydranautics).

Flexible Design: A Single-Pass or Double-Pass RO system to meet your target conductivity.

Intelligent Maintenance: With an automatic flush and Clean-in-Place (CIP) system.

Treatment Effectiveness: Salt, organic, bacteria and virus rejection is >99%. The conductivity of the product water can be stably <10 µS/cm.

Advanced Polishing & Disinfection Systems

Ultra-pure water and sterile assurance

Ultrafiltration (UF) System: For removal of colloids and high molecular weight organics.

EDI (Electrodeionization) Systems: These systems are capable of delivering ultra-pure, reagent grade water on a continuous basis free of chemicals.

High Efficiency Ozone Mixing Tower(SUS316):Strong end sterilization, kill Bacteria and gest organics, tastes better.

Ultraviolet (UV) Sterilizers: Chemical-free microbial disinfection, frequently used in conjunction with ozone to provide a dual-barrier protection.

Blending, Storage & Control

The Perfect Grind Consistent Delivery

Mineralization / pH correction skids: Slurries the minerals, and adjusts the pH to taste or process specification.

RO Product Water Tank (SUS304 ): With 0.22µm vent filter to avoid airborne contamination.

Integrated Control & Monitoring Panel: Monitor flow, pressure, conductivity and pH in real-time. Includes automatic pump interlocks and alarms.

Application Areas: Industries We Serve

Our systems are engineered for diverse purity requirements:

  • Beverage ProductionBottled water, carbonated soft drinks, juices, beer brewing water.

  • Food Processing: Ingredient water, cleaning-in-place (CIP) final rinses.

  • Pharmaceutical & Cosmetics: Process water, ingredient water (following GMP principles).

  • Electronics & Power: Ultra-pure water for wafer cleaning, boiler feed water.

  • Hospitality & Commercial: Hotel, restaurant, and school water supply.

  • Specialty Applications: Seawater/brackish water desalination, wastewater reuse.

Technical Specifications & Capacity Range

System ComponentKey Performance IndicatorsStandard Capacity RangeCore Material
Multimedia FilterEffluent Turbidity: <0.5 NTUCustom designs from 100 LPH to 7500 m³/dayFRP / SS304 Lined
Activated Carbon FilterResidual Chlorine: ≤0.1 mg/LCustom designs from 100 LPH to 7500 m³/dayFRP / SS304
Water SoftenerOutput Hardness: <1.5 mg/L (as CaCO₃)Custom designs from 100 LPH to 7500 m³/dayFRP / SS304
Reverse Osmosis SystemSalt Rejection: >99%; Conductivity: <10 µS/cm*500 LPH to 5000 m³/daySS304 / SS316
Ozone GeneratorOzone Concentration: 10-20% wtSized to application flow rateSUS316 Contact Tower
Control SystemPLC / Touchscreen InterfaceFully Automatic

*Conductivity depends on feed water TDS. Specifications are project-dependent.

we’re here to all your questions

It ensures accurate design. Guessing contaminants can lead to under- or over-sized systems, risking failure or extra cost.

Covers material and workmanship defects for core equipment, with FAT, installation supervision, commissioning, and operator training.

Yes. We use specialized RO membranes and energy recovery devices, with critical pre-treatment for challenging sources.

Systems have automatic backwash and CIP cycles. Manuals and lifetime technical support are provided. Consumables have predictable lifecycles.

Top-tier membranes plus proper pre-treatment, optimal pumps, and intelligent controls ensure stable performance and lower total cost of ownership.

Focused on Filling, Driven by Quality.